| FILE TYPE LINK LEGEND: | HTML | PPTX & PPT | XLSX | DOCX & DOC | JPG, PNG, GIF |
→ PICO Wiki ARCHIVED SITE - HOME
Telecon 20180206
Attending: Brian, Roger, Jacques, Julian, Tom, Toki, Kris, Hannes, Shaul, Karl, Qi
Notes by : Karl/Qi
Agenda
- Focal Plane Configuration (Kris, Karl, others) focal plane slides (.pdf)
- including ADR and Readout boards
- ADR drawing:PIPER ADR CAD (.pdf)
- Cosmic Rays (Jeff f.; Roger)
Notes
Focal Plane Configuration
- Orientation of scan VS orientation of detector rows
- Kris repeated the concern again from last week; with the hexagone wafers and current scan strategy, is it important to align rows of detectors with direction of scan?
- multiple detectors on a row can scan over the same track if they are aligned with direction of scan
- Shaul pointed out that even now there are detectors are one row, every other column though
- It's not very clear if this matters
- Spin rate is dominant over precession, so scan direction is about straight from left to right as shown
- Shaul: each pixel has both polarizations; we want Q and U pairs, thus the word “detector” may be misleading here
- Jacques: arrangement of focal plane, cross scan sampling; shaul: we will take look into Jaques's paper about cross scan sampling in terms of spin, precession etc.
- Kris: faster precession, if compare 10 days to 10 hrs, gives better sky map coverage; however, if compare 10 hrs to 2 hrs, not sure if it makes a big difference
- Jacques: holes on sky map will affect systematics over the focal plane
- Shaul: fundamental questions have not be addressed, Q and U layout has not been done
- Q and U alignment is flexible within wafer
- ADR
- shaul: current model has a tank next to focal plane for ADR, but it does not need to be there there
- Tom: PIPER ADR
- continuous ADR, 4 stages
- stage 1, attached to brown color plate, which attach the focal plane
- about 9
by 8by 3'' - For PICO, one more intermediate stage, stable temperature; every 6 days, one extra ADR stage; so 5 stages in arrangement, slight larger than PIPER's
- 0.1 K fluctuates between magging and demagging; Tom will look into it how large the fluctuation is for next week
- Focal Plane
- change: 1)central wafer, split into three: F and GHI;2) 4mm space between edges of wafers based on different experiments (4.2mm for EBEX, 4-5mm for POLARBEAR, 5.5mm for BICEP)
- Shaul: let's make space to 5mm
- less F detectors, more GHI, same numbers for others
- wire bonding
- traditional: edge of wafer, constrains # you can bond; for F G H I, not enough space
- “bump-bonding”, instead of the edge, you can wire bond the entire wafer, needed for GHI
- readout
- for TDM, 4 mm^2; for FDM, mainly due to large capacitors, 50-80 mm^2
- FGHI need some special packing, working on
- sizes of mirrors
- we need to increase mirror sizes if we want to use more diffraction limited field of view
- dimensions are shown in the slides
Cosmic Rays
- Roger: signals long-time constant spikes
- TES for X-rays, they do not see it as a driven issue; worth looking into it
Last modified: 2018/02/07 15:54 by wenxx181

